Power Analyzer Vitrek PA900
Laboratory-grade accuracy and bandwidth, exceptional touchscreen experience and display modes, multi-channel modular options, enabling highly efficient measurement and analysis.
- High precision and industry-leading low noise
- Measures up to 500 harmonics, compliant with avionics standards
- Large high-resolution touchscreen displays all necessary data
- Built-in data logger – Supports up to 16 optional data points
- Customizable data display
- Timebase and trigger settings – Capable of capturing inrush current
- Vector display function – Supports up to 10 voltage and current channels
- History recording – Automatic continuous data measurement
- Complies with EN50564:2011 standards
- High effective sampling rate – Enables cycle signal analysis
- Modular design with 4 channels, customizable with various module configurations
- Swappable modules without calibration requirements
- Virtual Power Analyzer (VPA) function for synchronized power measurement
- VPA efficiency comparison – Power loss and efficiency percentage across configurations
- Ethernet (LAN) and USB interfaces
- Optional multi-device connection module for measurement of hundreds of channels
- Front-panel USB interface – Supports data logging
- CE certified
Voltage Measurement
- Maximum accuracy up to 0.03%
- Bandwidth up to 3 MHz (3dB)
- Maximum voltage withstand: 1000 Vrms
Current Measurement
- Direct measurement up to 30 Arms
- Maximum accuracy up to 0.03%
- Bandwidth up to 5 MHz (3dB)
Modules
- X Module – For connecting voltage feedback CT
- MT Module – For torque and speed measurement of motors
Harmonics
The Vitrek PA900 displays up to 500 harmonics even at aviation power frequencies. Harmonics amplitude can be set to display in linear, relative linear, logarithmic, or relative logarithmic scales. Touching the harmonic bar on the screen allows selection of up to 8 harmonics for digital display of amplitude and phase. Harmonic limits can also be imported, and any out-of-limit harmonics will be highlighted.

Power Data
Quickly display V, A, W, VA, VAR, and PF metrics for any selected channel or grouping within the Virtual Power Analyzer (VPA). Additional data such as peak values, phase, crest factor, and results (WHr) can also be viewed. For customized data presentations, create personalized display screens using spreadsheet programs and upload them via USB or interface.

Scope View (Oscilloscope Simulation)
Offers oscilloscope-like waveform capture and analysis. Up to six signals can be displayed simultaneously, with scalable, offset, and color options for each signal. Timebase, triggering, and trigger position settings are fully adjustable. With measurement accuracy as high as 0.03%, it surpasses typical oscilloscope capabilities.

Cycle View (Per Cycle Display)
Displays voltage and/or current waveforms of the current cycle. Example waveforms illustrate snapshots of a 10V blue square wave and a 50:1 red zoomed-in view. Amplitude and zoom settings are highly adjustable, showcasing minute details with a sampling rate reaching 384 MSPS.

Vector (Polar Chart)
Displays vector representation of voltage and current for selected channels or VPA configurations on a polar chart. For multi-phase VPAs, interphase voltages and unmeasured neutral vectors are displayed. Users can enable up to 10 vectors and select color options for each.

History Records
Automatically retains all non-harmonic measurement results and selected harmonic data in continuous history. The HISTORY screen can graph up to four selected parameters, covering recording periods up to 397 days or zooming into 1/64 of the full range. Touchscreen controls facilitate cursor movement through the data.

Standby Power Measurement
The Vitrek PA900 is equipped with built-in standby power testing compliant with EN50564:2011 (formerly IEC62301). Press the STBY POWER button to initiate a measurement. All data is clearly displayed on a single screen for easy viewing and can be saved as image files to a connected USB device for reporting purposes. EN50564:2011 measurement methods, minimum test durations, and data logging are fully configurable. The PA900 can independently perform standby power measurements on each configured VPA.

Highly Flexible Modular Design
The Vitrek PA900 features a modular measurement design, balancing performance capabilities with budget constraints. The main unit supports four module slots, allowing combination of various channel configurations. Flexible design includes variable input current selection, with different current input ranges for each channel card option.
X Module: Optimized for external shunt and current sensor connections.

Key Features
- High precision and industry-leading low noise
- Capable of measuring up to 500 harmonics, compliant with avionics harmonic measurement standards. The histogram allows direct touch interaction to obtain amplitude and phase data.
- Large high-resolution touchscreen displays all the information you need, and the user-friendly interface enables faster test initiation.
- Modular design allows flexible combinations of three different channel card types.
- Built-in data recorder – Record up to 16 selectable data results to USB or internal storage, with intervals ranging from 10ms to 100 hours.
- Customizable measurement information display – Choose display colors, font size, position, and measurement parameters.
- Equipped with time base and triggering settings – Similar to an oscilloscope, enabling surge current capture.
- Vector display function – Visualizes up to 10 fundamental voltage and current vectors.
- Historical recording – Like a DVR, the PA900 automatically maintains a continuous history of measurement data, allowing you to review or download any data from the record.
- Compliant with EN50564:2011 testing, saving all necessary data on a single screen.
- High effective sampling rate – For periodic signal analysis, the PA900 achieves 384 MSPS.
- Measurement resolution – S&W-type channel cards at 22-bit resolution, A-type at 24-bit resolution.
- Supports up to three virtual power analyzers (VPAs) for three-phase measurement or input/output efficiency testing, eliminating the need for separately connected power analyzers for synchronized power measurements.
- VPA efficiency comparison – Includes: power sums of IN, MIDDLE, and OUT, power losses between groups, and inter-group efficiency percentages.
- VPA multi-channel wiring – Each VPA can be configured as 2ø3w (2-channel), 3ø3w (2-channel), 3ø3w (3-channel), or 3ø4w (3-channel).
- Supports Ethernet and USB (client) control interface.
- Optional multi-unit module (Option MU) connection enables combining multiple PA900 units, allowing measurement of up to thousands of channels.
- Front panel USB interface – For data recording, “screenshot” functionality, and easy import/export of display/measurement settings and custom data screen displays.
- MT-type channel cards – For motor torque and speed measurement inputs.
- CE certified.
Specifications
Model | Description |
---|---|
PA901AD | PA900 Series Power Analyzer with a Single High Accuracy AD Channel Card |
PA902AD | PA900 Series Power Analyzer with Two High Accuracy AD Channel Cards |
PA903AD | PA900 Series Power Analyzer with Three High Accuracy AD Channel Cards |
PA904AD | PA900 Series Power Analyzer with Four High Accuracy AD Channel Cards |
PA900 | PA900 Series Power Analyzer with a Single High Accuracy AD Channel Card |
SD | Standard Dual Current Channel Card |
SH | Standard High Current Channel Card |
SX | Standard External Current Channel Card |
AD | Hi Accuracy Dual Shunt Channel Card |
AH | Hi Accuracy High Current Channel Card |